Does Type 1 Diabetes Mellitus Affect the Shear Wave Velocity of the Thyroid Gland of Children Without Autoimmune Thyroiditis?
ULTRASOUND QUARTERLY, cilt.33, sa.3, ss.225-228, 2017 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 33 Sayı: 3
- Basım Tarihi: 2017
- Doi Numarası: 10.1097/ruq.0000000000000301
- Dergi Adı: ULTRASOUND QUARTERLY
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Sayfa Sayıları: ss.225-228
- Anahtar Kelimeler: acoustic radiation force impulse elastography, thyroid, type 1 diabetes, ELASTOGRAPHY, ADOLESCENTS, DIAGNOSIS, NODULES
- Ondokuz Mayıs Üniversitesi Adresli: Evet
Özet
Objective: The aim of this study is to evaluate the shear wave velocity (SWV) of the thyroid gland with acoustic radiation force impulse elastography in children with type 1 diabetes mellitus (T1D).