Comparison of Electrocoagulation and Chemical Coagulation for Heavy Metal Removal


Akbal F., Camci S.

CHEMICAL ENGINEERING & TECHNOLOGY, cilt.33, sa.10, ss.1655-1664, 2010 (SCI-Expanded) identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 33 Sayı: 10
  • Basım Tarihi: 2010
  • Doi Numarası: 10.1002/ceat.201000091
  • Dergi Adı: CHEMICAL ENGINEERING & TECHNOLOGY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.1655-1664
  • Anahtar Kelimeler: Chemical coagulation, Electrocoagulation, Heavy metals, Metal plating wastewater, POLISHING WASTE-WATER, OPERATIONAL PARAMETERS, DECOLORIZATION, WASTEWATERS, ELECTRODES, ALUMINUM, INDUSTRY, CR(VI), IRON
  • Ondokuz Mayıs Üniversitesi Adresli: Evet

Özet

Copper (Cu), chromium (Cr), and nickel (Ni) removal from metal plating wastewater by electrocoagulation and chemical coagulation was investigated. Chemical coagulation was performed using either aluminum sulfate or ferric chloride, whereas electrocoagulation was done in an electrolytic cell using aluminum or iron electrodes. By chemical coagulation, Cu-, Cr-, and Ni-removal of 99.9% was achieved with aluminum sulfate and ferric chloride dosages of 500, 1000, and 2000 mg L(-1), respectively. Removal of metals by electrocoagulation was affected by the electrode material, wastewater pH, current density, number of electrodes, and electrocoagulation time. Electrocoagulation with iron electrodes at a current density of 10 mA cm(-2), electrocoagulation time of 20 min, and pH 3.0 resulted in 99.9% Cu-, 99.9% Cr-, and 98% Ni-removal.