Impact of different sampling rates on precise point positioning performance using online processing service


Erol S., Alkan R. M., OZULU İ. M., İlçi V.

GEO-SPATIAL INFORMATION SCIENCE, cilt.24, sa.2, ss.302-312, 2021 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 24 Sayı: 2
  • Basım Tarihi: 2021
  • Doi Numarası: 10.1080/10095020.2020.1842811
  • Dergi Adı: GEO-SPATIAL INFORMATION SCIENCE
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Aquatic Science & Fisheries Abstracts (ASFA), CAB Abstracts, Communication Abstracts, Geobase, INSPEC, Directory of Open Access Journals, Civil Engineering Abstracts
  • Sayfa Sayıları: ss.302-312
  • Anahtar Kelimeler: Precise Point Positioning (PPP), online GNSS post-processing service, high-rate GNSS, sampling rate, monitoring structure behavior
  • Ondokuz Mayıs Üniversitesi Adresli: Evet

Özet

In this study, the effect of different sampling rates (i.e. observation recording interval) on the Precise Point Positioning (PPP) solutions in terms of accuracy was investigated. For this purpose, a field test was carried out in corum province, Turkey, on 11 September 2019. Within this context, a Geodetic Point (GP) was established and precisely coordinated. A static GNSS measurement was occupied on the GP for about 4-hour time at 0.10 second (s)/10 Hz measurement intervals with the Trimble R10 geodetic grade GNSS receiver. The original observation file was converted to RINEX format and then decimated into the different data sampling rates as 0.2 s, 0.5 s, 1 s, 5 s, 10 s, 30 s, 60 s, and 120 s. All these RINEX observation files were submitted to the Canadian Spatial Reference System-Precise Point Positioning (CSRS-PPP) online processing service the day after the data collection date by choosing both static and kinematic processing options. In this way, PPP-derived static coordinates, and the kinematic coordinates of each measurement epoch were calculated. The PPP-derived coordinates obtained from each decimated sampling intervals were compared to known coordinates of the GP for northing, easting, 2D position, and height components. According to the static and kinematic processing results, high data sampling rates did not change the PPP solutions in terms of accuracy when compared to the results obtained using lower sampling rates. The results of this study imply that it was not necessary to collect GNSS data with high-rate intervals for many surveying projects requiring cm-level accuracy.